1.切断电源,取下空调挂机的插头;
2.打开上层面板,取下两片空调滤网;<img src="http://sm0
1.alicdn.com/L1/723/75020/b0/32/c6/b032c6a807a56ce128cf6bd4e0d7235
8.jpg" alt="undefined" style="float:none;height: auto;width: auto"/><img src="http://sm0
1.alicdn.com/L1/723/31779/b8/b4/e3/b8b4e314ce5068b41b293b295f6057
1
7.jpg" alt="undefined" style="float:none;height: auto;width: auto"/><img src="http://sm0
1.alicdn.com/L1/723/90441/85/a4/35/85a4356567d0b867926fedb8ae3ac29
6.jpg" alt="undefined" style="float:none;height: auto;width: auto"/>
3.拧下主体面板和上层面板上所有螺丝,然后,松开卡扣,取下上层盖板;<img src="http://sm0
1.alicdn.com/L1/723/88254/49/36/53/49365356e804b8f682419afdf6c38d4
7.jpg" alt="undefined" style="float:none;height: auto;width: auto"/>
4.摁下挡板中间的白色螺栓,左侧用力弯曲挡板,松开卡扣,取下挡板。
取下两片风向挡片和不规则的白色小盖板;<img src="http://sm0
1.alicdn.com/L1/723/21096/3b/72/f2/3b72f291a6fc734289f71c413ba941b
1.jpg" alt="undefined" style="float:none;height: auto;width: auto"/><img src="http://sm0
1.alicdn.com/L1/723/25247/67/e5/d9/67e5d978a82922ed58becb376a83bfb
7.jpg" alt="undefined" style="float:none;height: auto;width: auto"/>
5.松开黄色电线和灰色电线,解除卡扣并向上用力,卸下主体面板;<img src="http://sm0
1.alicdn.com/L1/723/35351/f4/9f/a9/f49fa9943e2e6da665748e4b674f7370.jpg" alt="undefined" style="float:none;height: auto;width: auto"/>
6.用硬毛刷和喷水壶清洗空调挂机的金属冷凝片、滚轴、排水管口。
自然晾干所有空调配件,依序安装主体面板、上层面板、拧上螺丝、复位电线和白色小盖板、风向挡片、挡板、滤网即可。
原因:
1.空调启动或停机时,内机塑料件因温度变化发生胀缩而发出的声音属正常现象。
还有某些管路因为热胀冷缩导致变形贴到了压缩机或者金属外壳上导致共振。
2.内外机固定墙壁是否结实,墙体固定螺丝松动或变形易导致这种情况。
3.检查室内外连接管是否固定好,有无和室外机或其他物体发生碰撞。
4.空调启动或停机时,系统内冷媒在达到平衡之前会发出较响流动声,属正常现象。
1.送风系统故障。
过滤网脏堵,潮湿环境下使用低风档,风量如果偏小,内机蒸发温度降低,蒸发器结霜甚至结冰,时间一长导致漏水;
2.排水系统故障。
主要包括内机前后导水槽、排水管、管道包扎、排水泵故障等,当空调使用长时间后,导水槽、排水管都可能被脏物堵塞漏水,导水槽等因注塑原因有裂缝、连接管接头处包括不好,排水管安装时被压扁都会引起漏水;
3.系统缺氟和蒸发器半堵。
在蒸发器半堵的情况下,两个流路间温差较大,长管翅片凝结大量冷凝水随风吹出,因冷热空气在风道内交汇,水蒸气在风道内凝结,最后导致漏水;
4.安装问题导致漏水。
主要集中在新装机上,或是冬季安装的空调,因安装不水平或排水管、连接管接头未包扎好。